Time Electronics 5080

 
A precision calibrator designed to provide rapid high accuracy calibration of portable appliance testers and insulation/continuity testers. The 5080 PAT calibrator has functions for earth bond, insulation, leakage, touch leakage, and load test.

Housed in a robust safety case the 5080 is easily portable and ideal for field calibration work. It is battery powered, which ensures isolation and prevents inaccuracies due to stray leakage. Features include safety interlock that prevents contact with earth bond studs during insulation and leakage tests, and an LCD display for voltage and current.

The 5080 is a dedicated solution for PAT testers and part of the electrical testing calibration range from Time Electronics. Other models include the 5030 electrical tester calibrator for RCD, loop, insulation, earth testers and multifunction installation testers. For insulation testers the 5069 InsCal is a portable instrument with resistance up to 100GOhm, and 10kV operation.
Technical Specifications Earth Bond: Calibrated Low Value Resistive Load
Values / Accuracy 20mΩ, accuracy 5%190mΩ, 210mΩ, 950mΩ, 1.050mΩ, 1.08Ω, 2Ω, 10Ω, 18Ω, accuracy 1%
Open circuit voltage measurement Range: 0 to 20VAccuracy: 0.25% of full scale
High current AC measurement Range: 0 to 50A ACAccuracy: 0.5% of reading +/- 0.2A
Low current AC measurement Range: 0 to 2A ACAccuracy: 0.5% of reading +/- 2mA
Low current DC measurement Range: 0 to 2A DCAccuracy: 1% of reading +/- 2mA


Insulation: Calibrated High Value Resistive Load
alues / Accuracy 95kΩ, 105kΩ, 500kΩ, 950kΩ, 1.05MΩ, 5MΩ, 10MΩ, accuracy 0.1%20MΩ, 50MΩ, 100MΩ, accuracy 1.0%
Open circuit voltage measurement Range: 0 to 1kV DCAccuracy: 0.25% of full scale
Current measurement Range: 0 to 20mA DC. Accuracy: 0.25% of full scale


Leakage: Resistive Load for Leakage Currend
Nominal Leakage Currents At 230V AC of 0.5, 1, 2, 5, 10, 15mA
Mains voltage measurement Range: 0 to 500V ACAccuracy 0.25% of full scale
Leakage current measurement Range: 0 to 20mA ACAccuracy 0.25% of full scale


Touch Leakage: Constant Current Source for Touch Leakage Current
urrent 1.9mA AC 50 +/-5 Hz, into 2K2 maximum load resistance
Current measurement Range: 0 to 2mA AC. Accuracy: 0.25% of full scale


Load Test: Connection of External Load VIA AN IEC Connector
Mains voltage measurement Range: 0 to 500V ACAccuracy: 0.25% of full scale
Load current measurement Range: 0 to 13A ACAccuracy: 0.5% of full scale


General Specifications
Power Internal battery 6V re-chargeable NiCad, >200 hrs between charges.
Dimensions W406 x H175 x D330mm
Weight 5.5kg
Supplied With 4mm terminal box adaptor, 110V adaptor, IEC connector (for external load), battery charger, and user manual.
Optional Extras Calibration certificates traceable NPL and UKAS
Country of Origin UK