Time Electronics 5025E

 
Calibration at an Affordable Price A precision multi-product calibrator designed for wide calibration workload coverage at an affordable cost. Accurately test and verify both traditional and new test equipment with a calibrator that meets both technical and budget requirements. The 5025E is ideal for companies requiring a calibrator that can be implemented quickly and easily, providing immediate return on investment. With increased capabilities it can be used as a multimeter calibrator and much more.

The 5025E is fitted with AC/DC voltage to 1050V, AC/DC current to 22A, digital frequency to 10MHz, decade resistance to 1GΩ, simulated variable resistance from 40Ω to 40kΩ, conductance, capacitance, thermocouple and PT100 simulation.

An optional enhanced performance pack increases the specification of certain functions for wider calibration coverage. It provides full range variable resistance to 120MΩ, extended temperature functions, extended capacitance, and increased ACV frequency bandwidth. Also available are oscilloscope and power calibration options.

In addition external adaptors are available for clamp meter calibration (up to 1100A) and optical tachometer calibration. Also available is a power amplifier which increases the 5025E's AC/DC voltage output drive capabilities to 100mA. This addition allows even the most demanding analogue instruments to be tested.

Multi Instrument and Device Calibration The 5025E can calibrate various instruments and devices; bench and handheld multimeters, frequency meters, ohm meters, AC/DC millivoltmeters, thermocouple and PT100 meters, clamp meters, and many other measurement devices. By adding internal options the 5025E can calibrate oscilloscopes, timer/counters, power meters and more.

For more information see the 5025 Series Calibration Capabilities Chart showing the DUT coverage of the 5025E and 5025C calibrators.

Simple Operation Functions and ranges are easily accessed from the front panel. Increase and decrease keys per digit, are used to quickly set the output value. Deviation control then enables the user to finely adjust the output value as a percentage (+/- 9.999%). All this information is shown on a clear, easy to read LED display.

Virtual Control Software The 5025E is supplied as standard with Time Electronics' windows based Virtual Control software. It allows quick and direct input of any value required. The remote SCPI command is displayed to help users develop custom applications.

EasyCal Calibration Software Connect the 5025E to a PC/Laptop (via RS-232 or USB) installed with Time Electronics' EasyCal software and automate the calibration process. This provides increased speed of calibration and consistency of results. Produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.
Standard Functions
Function Range / Values Best 1 year Specification
Voltage DC 0 to ± 1050V ± 40ppm of setting
Current DC 0 to ± 22A1100A with clamp meter adaptor (option 9780) ± 120ppm of setting
Voltage AC 1mV to 1050V (20Hz to 20kHz, sine-wave) ± 0.04% of setting
Current AC 10μA to 22A (20Hz to 1kHz, sine-wave)100A with current transformer (option 9790) 1100A with clamp meter adaptor (option 9780) ± 0.07% of setting
Decade Resistance 10Ω, 100Ω, 1kΩ, 10kΩ, 100kΩ, 1MΩ, 10MΩ, 100MΩ & 1GΩ ± 60ppm of setting
Conductance 100ms to 1ns (Fixed values, decade steps) ± 60ppm of setting
Simulated Resistance 40Ω to 40kΩ (Variable) ± 0.02% of setting
Thermocouple Simulation -200 to 1800°C (Type J, K, R, T, S, B, E, N) ± 0.3°C
PT100 Simulation -140°C to 850°C ± 0.25°C
Capacitance 1nF, 10nF, 20nF, 50nF, 100nF, 200nF, 500nF, 1μF ± 0.25%
10MHz Digital Frequency/Period 0.1Hz to 10MHz / 100ns to 10s ± 20ppm of setting


Option 9770: Oscilloscope Calibration
Function Range / Values Best 1 year Specification
Amplitude 2mV to 200V and 1mV to 2V 50Ω (Square-wave or DC) ± 0.05%
Frequency/Period 0.1Hz to 100MHz / 10ns to 10s (fixed values 1, 2, 5 sequence) ± 20ppm
Duty Cycle 3 frequencies: 100Hz, 1kHz, 10kHz, settable from 0 to 100%
Fast-Rise < 400ps. Bandwidth checking up to 400MHz
Option 9783: Frequency ReferenceFor timer/counter calibration 0.1Hz to 10MHz enhanced frequency accuracy reference ± 0.1ppm
Option 9769: 2.2GHz Sweep 50MHz to 2.2GHz levelled sine-wave (0.5, 1, 1.5V pk-pk) Amplitude ± 1%, Frequency ± 20ppm


Option 9797: Power Calibration
Function Range / Values Best 1 year Specification
Power 22A, 1050V, 23kW, 45 to 400Hz ACV: 0.03%, DCV: 0.01%.ACI: 0.1%, DCI: 0.03%
Phase/Power Factor ± 90°/ 0.00 to 1.00PF ± 0.3°


Option 9702: Enhanced Performance Pack (Added Values/Types Shown in Bold Where Applicable)
Function Range / Values Best 1 year Specification
Full Range Resistance 1Ω to 120MΩ (variable) ± 100ppm of setting
RTD Simulation -180 to 850°C. Type PT100, PT200, PT500, PT1000 ± 0.03°C
Extended Thermocouple Simulation -210 to 2315°C. Type J, K, R, T, S, B, E, N, C, L, U ± 0.05°C
Extended Capacitance 1nF, 10nF, 20nF, 50nF, 100nF, 200nF, 500nF, 1μF, 10μF, 20μF, 50μF, 100μF ± 0.2% of setting
Extended AC Voltage Frequency 1mV to 200mV/100kHz, 200mV to 2V/100kHz, 2V to 20V/100kHz ± 0.05% of setting


General Specifications
Warm up 30 minutes to full accuracy
Interfaces RS-232 and USB
Temp Performance Operating: 5 to 40°C, Full Spec: 23°C +/- 5°C, Storage: -10°C to 50°C
Operating Humidity < 80% non condensing
Operating Altitude 0 to 3km. Non operating: 3km to 12km
Line Power 100 to 230V AC 50/60 Hz. 200W maximum
Dimensions W455 x H155 x D480mm
Supplied With Basic test lead set, virtual control software, operation manual, RS-232 cable, and USB adaptor/cable
Country of Origin UK